ADAS1000 Low Power, 5-Electrode Electrocardiogram (ECG) Analog Front End with respiration measurement and pace detection)

ECG: Monitor & Diagnostic

The ADAS1000 measures electro cardiac (ECG) signals, thoracic impedance, pacing artifacts, lead on/off status and outputs this information in the form of a data frame supplying either Lead/Vector or Electrode data at programmable data rates. Its low power and small size make it suitable for portable, battery powered applications. The high performance also makes it suitable for higher end diagnostic machines.

The ADAS1000 is designed to simplify the task of acquiring and ensuring quality ECG signals. Value-added cardiac postprocessing is executed externally on a DSP, microprocessor or FPGA. Several digital output options ensure flexibility when monitoring and analyzing signals. The ADAS100

0 provides a low power, small data acquisition system for biopotential applications.

Auxiliary features that aid in better quality ECG signal acquisition include: multi-channel averaged driven lead, selectable reference drive, fast over load recovery, flexible respiration circuitry returning magnitude and phase information, internal pace detection algorithm operating on 3 leads and option of AC or DC leads off detection.

Since ECG systems span different applications, the ADAS1000 features a flexible power/noise scaling architecture where the noise can be reduced at the expense of increasing power consumption. Signal acquisition channels may be shutdown to save power. Data rates can be reduced to save power.

To ease manufacturing tests, development, as well as offer holistic power-up testing, the ADAS1000 offers a suite of dc and ac test excitation via the CAL DAC, CRC redundancy testing in addition to read-back of all relevant register address space.

The ADAS1000 is available in two package options, either a 56 lead LFCSP or a 64 lead LQFP package and is specified over -40°C to +85°C temperature range. The ADAS1000 is a full featured 5 channel ECG including respiration and pace detection, while the ADAS1000-1 offers only ECG channels with no respiration or pace features. Similarly the ADAS1000-2 is a subset of the main device and is configured for gang purposes with only ECG channels enabled (no respiration, pace, RLD, etc).

APPLICATIONS

Features and Benefits
  • Biopotential signals in; digitized signals out
  • 5 acquisition (ECG) channels + 1 driven lead
  • Parallel ICs for up to 10+ Electrode measurements
  • AC and DC Leads Off Detection
  • Internal Pace Detection Algorithm on 3 leads
    -- Support for users own digital pace
  • Thoracic Impedance Measurement (internal/external path)
  • Selectable Reference Lead
  • See datasheet for additional features
Analog to Digital Converters
Reference Designs
Data Sheets
Documentnote
ADAS1000/ADAS1000-1/ADAS1000-2: Low Power, Five Electrode Electrocardiogram (ECG) Analog Front End Data Sheet (Rev. B)PDF 1478 kB
Application Notes
Documentnote
AN-1251: ADAS1000 Cyclic Redundancy Code (Rev. 0)PDF 93 kB
User Guides
Documentnote
UG-426:ADAS1000 ECG Front-End Evaluation Board for Demonstration and DevelopmentPDF 2231 kB
Order Information
Part NumberPackagePacking QtyTemp RangePrice 100-499Price 1000+RoHS
ADAS1000BCPZ ProductionLFCSP:LEADFRM CHIP SCALEOTH 260-40 to 85C19.218.24Y
ADAS1000BCPZ-RL ProductionLFCSP:LEADFRM CHIP SCALEREEL 2500-40 to 85C018.24Y
ADAS1000BSTZ Production64 ld LQFP (10x10mm)OTH 160-40 to 85C19.218.24Y
ADAS1000BSTZ-RL Production64 ld LQFP (10x10mm)REEL 1500-40 to 85C018.24Y
Evaluation Boards
Part NumberDescriptionPriceRoHS
EVAL-ADAS1000SDZEvaluation Board199Y
EVAL-SDP-CB1ZEvaluation Controller Board99Y
Reference Materials
ADAS1000/ADAS1000-1/ADAS1000-2: 低功耗、5电极心电图(ECG)模拟前端 (Rev. A) adas1000
ADAS1000/ADAS1000-1/ADAS1000-2: Low Power, Five Electrode Electrocardiogram (ECG) Analog Front End Data Sheet (Rev. B) adas1000
CN0308 设计和集成文件 adp151
ADAS1000参考代码 adas1000
AN-1251: ADAS1000 Cyclic Redundancy Code (Rev. 0) adas1000
UG-426:用于演示和开发的ADAS1000 ECG前端评估板 adas1000
UG-426:ADAS1000 ECG Front-End Evaluation Board for Demonstration and Development adas1000
CN-0308:电池供电病人监护应用中ECG前端的供电 adp151
Transthoracic Impedance Measurements in Patient Monitoring adas1000
MS-2210:高速ADC的电源设计 ad9861
MS-2160:ECG设计挑战的应对策略 adas1000
MS-2126:多生理参数病人监护 adas1000
MS-2125:共模抑制与ECG子系统有何关系 以及用来实现出色性能的技术 adas1000