Single-pole master disconnect switches. Will disconnect the battery circuit only.
Available Attributes
(See Specifications tab for exact part number details)
Catalog # | Case | Rating | Terminals | Contacts | Description | Details | Mounting stem |
---|---|---|---|---|---|---|---|
2484 | Plated Steel | 12 Vdc; 20A continuous 125A intermittent 15 sec. On 5 min. Off (UL rating) | two 3/8 copper studs | Copper | Single Pole - Two Positions: Off-On | brass 3/4 - 16 thread 23/32 long fits panel through 3/16 thick | |
2484-02 | Plated Steel | 6-36 Vdc; 175A continuous 1000A intermittent 15 sec. On 5 min. Off | two 3/8 copper studs | Silver | Single Pole - Two Positions: Off-On | brass 3/4 - 16 17/32 long fits panel through 1/4 thick | |
2484-03 | Plated Steel | 6-36 Vdc; 175A continuous 1000A intermittent 15 sec. On 5 min. Off | two 3/8 copper studs | Silver | Same as 2484-02 - with o-ring seal in the operating shaft | Single Pole - Two Positions: Off-On | brass 3/4 - 16 17/32 long fits panel through 1/4 thick |
2484-06 | Plated Steel | 6-36 Vdc; 175A continuous 1000A intermittent 15 sec. On 5 min. Off | Silver | Weather resistant O-ring seal in operating shaft - gasket-sealed terminal insulation and sealant in mounting stem and case | Single Pole - Two Positions: Off-On | brass 3/4 - 16 thread 23/32 long fits panel through 3/16 thick | |
2484-09 | Plated Steel | 6-36 Vdc; 175A continuous 1000A intermittent 15 sec. On 5 min. Off | two 3/8 copper studs | Copper | Same as 2484-16 with copper contacts and without UL label | Single Pole - Two Positions: Off-On | brass 3/4 - 16 thread 23/32 long fits panel through 3/16 thick |
2484-16 | Plated Steel | 250A at 6V 125A at12V intermittent; 40A at 6V 20A at 12V continuous | two 3/8 copper studs | Silver | Single Pole - Two Positions: Off-On | brass 3/4 - 16 thread 23/32 long fits panel through 3/16 thick | |
2484-19 | Plated Steel | 6-36 Vdc; 175A continuous 1000A intermittent 15 sec. On 5 min. Off | two 3/8 copper studs | Silver | Single Pole - Two Positions: Off-On | brass 3/4 - 16 17/32 long fits panel through 1/4 thick | |
2484-A | Plated Steel | 6-36 Vdc; 175A continuous 1000A intermittent 15 sec. On 5 min. Off | two 3/8 copper studs | Silver | Single Pole - Two Positions: Off-On | brass 3/4 - 16 thread 23/32 long fits panel through 3/16 thick |