MCP6V01RD-TCPL MCP6V01 Thermocouple Auto-Zeroed Reference Design

The MCP6V01 Thermocouple Auto-Zeroed Reference Design demonstrates how to use a difference amplifier system to measure electromotive force (EMF) voltage at the cold junction of thermocouple in order to accurately measure temperature at the hot junction. This can be done by using the MCP6V01 auto-zeroed op amp because of its ultra low offset voltage (VOS) and high common mode rejection ratio (CMRR)

Devices Supported: MCP6V01 Auto-Zeroed Op Amp

  • Use a difference amplifier system as an analog sensor conditioning circuit
  • Use the K-type thermocouple to sense temperature
  • Temperature range is from -100°C to +1000°C
  • Use MCP9800 Temperature Sensor for cold junction compensation
  • Use the USB interface to transfer data to PC
  • Test points for bench work
Documentation & Software
AppNotesLast UpdatedSize
AN1306 - Thermocouple Circuit Using MCP6V01 and PIC18F255012/18/2009 8:45:31 AM255KB
MCP6V01/2/3 Data Sheet4/25/2014 4:20:54 PM999KB
MCP6V01 Thermocouple Auto-Zeroed Reference Design12/19/2008 10:24:11 AM654KB
MCP6V01 Thermocouple Auto-Zeroed Reference Design Firmware8/29/2008 11:42:40 AM300KB
MCP6V01 Thermocouple Auto-Zeroed Reference Design Gerbers8/28/2008 2:34:50 PM271KB
MCP6V01/2/3 Data Sheet MCP6V03
AN1306 MCP6V27
MCP6V01/2/3 Data Sheet MCP651EV-VOS
MCP6V01 Thermocouple Auto-Zeroed Reference Design MCP6V01RD-TCPL
MCP6V01 Thermocouple Auto-Zeroed Reference Design Firmware MCP6V01RD-TCPL
MCP6V01 Thermocouple Auto-Zeroed Reference Design Gerbers MCP6V01RD-TCPL
MCP6V01RD-TCPL