The MMA16xxW and MMA16xxNWR2 inertial satellite sensors support the DSI communication protocol for front and side crash detection in automotive applications.
Name/Description | Type | Modified Date |
---|---|---|
NXP® MMA16xxKW DSI Inertial Sensor - Data Sheet (REV 5.1) PDF (439.6 kB) MMA16XXKW | Data Sheets | 25 Mar 2013 |
NXP® MMA16xxW and MMA26xxW Airbag Sensors (REV 1) PDF (524.4 kB) MMAX6XXWFS | Fact Sheets | 17 Jul 2012 |
Name/Description | Modified Date |
---|---|
NXP® MMA16xxKW DSI Inertial Sensor - Data Sheet (REV 5.1) PDF (439.6 kB) MMA16XXKW | 25 Mar 2013 |
Name/Description | Modified Date |
---|---|
NXP® MMA16xxW and MMA26xxW Airbag Sensors (REV 1) PDF (524.4 kB) MMAX6XXWFS | 17 Jul 2012 |
Name/Description | Modified Date |
---|---|
SENSSELECT, Sensor Products - Selector Guide (REV 1) PDF (133.5 kB) SENSSELECT | 20 Feb 2015 |
Name/Description | Modified Date |
---|---|
SENSOR AIRBAG ACCELEROMETER 6X6 QFN ASSEMBLY TRANSFER FROM AMKOR KOREA K1 TO AMKOR PHILIPPINES P3 FACILITY (REV 0) HTM (5.9 kB) PCN16158A | 01 Aug 2014 |
Product | Status | Status | Budgetary Price excluding tax(US$) | SafeAssure Functional Safety | Acceleration (g) | Accelerometer output | Ambient Operating Temperature (Min-Max) (°C) | Sensing Axis | Special Features Acceleration | Start up response time (Typ) (ms) | Rolloff Frequency (Typ) (Hz) | Sensitivity Digital (Typ) (Cnts/g) | Supply Voltage (Min-Max) (V) | Interface Supply Voltage (Min-Max) (V) | Zero G Output (Typ) (V) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MMA1631NKW | Active | 1K @ US$3.08 | Quality Managed | 312 | DSI | -40 to 125 | Z | Low Pass Filter, Self Test | 5 | 400 | 1 | 6.3 to 30 | |||
MMA1618KW | Active | 1K @ US$3.21 | Quality Managed | 187 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 6.3 to 30 | ||||
MMA1618KWR2 | End of Life | 1K @ US$3.21 | Quality Managed | 187 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 6.3 to 30 | ||||
MMA1631NKWR2 | End of Life | 1K @ US$3.08 | Quality Managed | 312 | DSI | -40 to 125 | Z | Low Pass Filter, Self Test | 5 | 400 | 1 | 6.3 to 30 | |||
MMA1605NWR2 | No Longer Manufactured | 50 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 10 | 6.3 to 30 | |||||
MMA1618NW | No Longer Manufactured | 187 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 2 | 6.3 to 30 | |||||
MMA1631WR2 | No Longer Manufactured | 312 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 1 | 6.3 to 30 | |||||
MMA1631W | No Longer Manufactured | 312 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 1 | 6.3 to 30 | |||||
MMA1606WR2 | No Longer Manufactured | 62.5 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 8 | 6.3 to 30 | |||||
MMA1612NW | No Longer Manufactured | 125 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 4 | 6.3 to 30 | |||||
MMA1606NWR2 | No Longer Manufactured | 62.5 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 8 | 6.3 to 30 | |||||
MMA1605WR2 | No Longer Manufactured | 50 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 10 | 6.3 to 30 | |||||
MMA1618NWR2 | No Longer Manufactured | 187 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 2 | 6.3 to 30 | |||||
MMA1612NWR2 | No Longer Manufactured | 125 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 4 | 6.3 to 30 | |||||
MMA1606NW | No Longer Manufactured | 62.5 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 8 | 6.3 to 30 | |||||
MMA1631NWR2 | No Longer Manufactured | 312 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 1 | 6.3 to 30 | |||||
MMA1631NW | No Longer Manufactured | 312 | DSI | -40 to 125 | Z | Self Test, Low Pass Filter | 5 | 400 | 1 | 6.3 to 30 | |||||
MMA1605NW | No Longer Manufactured | 50 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 10 | 6.3 to 30 | |||||
MMA1605W | No Longer Manufactured | 50 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 10 | 6.3 to 30 | |||||
MMA1606W | No Longer Manufactured | 62.5 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 8 | 6.3 to 30 | |||||
MMA1618WR2 | No Longer Manufactured | 187 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 2 | 6.3 to 30 | |||||
MMA1618W | No Longer Manufactured | 187 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 2 | 6.3 to 30 | |||||
MMA1612W | No Longer Manufactured | 125 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 4 | 6.3 to 30 | |||||
MMA1612WR2 | No Longer Manufactured | 125 | DSI | -40 to 125 | Z | Low Pass Filter | 5 | 400 | 4 | 6.3 to 30 |
Package Description | Outline Version | Packing | Product Status | Part Number | Chemical Content | RoHS / Pb FreeChina RoHS Lookup | MSL | PPT (°C) |
---|---|---|---|---|---|---|---|---|
QFN 16 6*6*1.98 P1 | 98ASA00090D | MPQ - 75 RAILPOQ - 1500 BOX | Active | MMA1605KW | MMA1605KW.pdf | 3 | 260 | |
MPQ - 75 RAILPOQ - 1500 BOX | Active | MMA1605NKW | MMA1605NKW.pdf | 3 | 260 | |||
MPQ - 75 RAILPOQ - 1500 BOX | Active | MMA1606KW | MMA1606KW.pdf | 3 | 260 | |||
MPQ - 75 RAILPOQ - 1500 BOX | Active | MMA1606NKW | MMA1606NKW.pdf | 3 | 260 | |||
MPQ - 75 RAILPOQ - 1500 BOX | Active | MMA1612KW | MMA1612KW.pdf | 3 | 260 | |||
MPQ - 75 RAILPOQ - 1500 BOX | Active | MMA1612NKW | MMA1612NKW.pdf | 3 | 260 | |||
MPQ - 75 RAILPOQ - 1500 BOX | Active | MMA1618KW | MMA1618KW.pdf | 3 | 260 | |||
MPQ - 75 RAILPOQ - 1500 BOX | Active | MMA1618NKW | MMA1618NKW.pdf | 3 | 260 | |||
MPQ - 75 RAILPOQ - 1500 BOX | Active | MMA1631KW | MMA1631KW.pdf | 3 | 260 | |||
MPQ - 75 RAILPOQ - 1500 BOX | Active | MMA1631NKW | MMA1631NKW.pdf | 3 | 260 | |||
MPQ - 2000 REELPOQ - 2000 BOX | End of Life | MMA1605KWR2 | MMA1605KWR2.pdf | 3 | 260 | |||
MPQ - 2000 REELPOQ - 2000 BOX | End of Life | MMA1605NKWR2 | MMA1605NKWR2.pdf | 3 | 260 | |||
MPQ - 2000 REELPOQ - 2000 BOX | End of Life | MMA1606KWR2 | MMA1606KWR2.pdf | 3 | 260 | |||
MPQ - 2000 REELPOQ - 2000 BOX | End of Life | MMA1606NKWR2 | MMA1606NKWR2.pdf | 3 | 260 | |||
MPQ - 2000 REELPOQ - 2000 BOX | End of Life | MMA1612KWR2 | MMA1612KWR2.pdf | 3 | 260 | |||
MPQ - 2000 REELPOQ - 2000 BOX | End of Life | MMA1612NKWR2 | MMA1612NKWR2.pdf | 3 | 260 | |||
MPQ - 2000 REELPOQ - 2000 BOX | End of Life | MMA1618KWR2 | MMA1618KWR2.pdf | 3 | 260 | |||
MPQ - 2000 REELPOQ - 2000 BOX | End of Life | MMA1618NKWR2 | MMA1618NKWR2.pdf | 3 | 260 | |||
MPQ - 2000 REELPOQ - 2000 BOX | End of Life | MMA1631KWR2 | MMA1631KWR2.pdf | 3 | 260 | |||
MPQ - 2000 REELPOQ - 2000 BOX | End of Life | MMA1631NKWR2 | MMA1631NKWR2.pdf | 3 | 260 | |||
No Longer Manufactured | MMA1605NW | MMA1605NW.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1605NWR2 | MMA1605NWR2.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1605W | MMA1605W.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1605WR2 | MMA1605WR2.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1606NW | MMA1606NW.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1606NWR2 | MMA1606NWR2.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1606W | MMA1606W.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1606WR2 | MMA1606WR2.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1612NW | MMA1612NW.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1612NWR2 | MMA1612NWR2.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1612W | MMA1612W.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1612WR2 | MMA1612WR2.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1618NW | MMA1618NW.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1618NWR2 | MMA1618NWR2.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1618W | MMA1618W.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1618WR2 | MMA1618WR2.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1631NW | MMA1631NW.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1631NWR2 | MMA1631NWR2.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1631W | MMA1631W.pdf | 3 | 260 | ||||
No Longer Manufactured | MMA1631WR2 | MMA1631WR2.pdf | 3 | 260 |