Differential/Gauge up to 115 kPa

OrderAccuracy (% Error) (Max) (%)Ambient Operating Temperature (Min-Max) (°C)Level of IntegrationOutput TypePortingPressure Measurement TypePressure Range Min-max (Min-Max) (kPa)Pressure Rating (Max) (kPa)Pressure Rating (Max) (psi)Supply Voltage (Min-Max) (V)Supply Voltage (Typ) (V)
MPX230xDT1-40 to 125CompensatedAnalogUnportedGauge0 to 40405.81 to 106
MPX40803-40 to 125IntegratedAnalogUnportedDifferential0 to 808011.64.85 to 5.355.1
MPX51002.5-40 to 125IntegratedAnalogAxial Port, Side Port, Dual Side PortsAbsolute, Gauge, Differential0 to 100100, 11514.5, 16.74.75 to 5.255
MPXV51002.5-40 to 125IntegratedAnalogSide Port, Axial Port, Dual Side PortsGauge, Absolute0 to 10010014.54.75 to 5.255
MPXx2050-40 to 125CompensatedAnalogSide Port, Unported, Dual Side Ports, Axial PortGauge, Differential0 to 505071 to 1610
MPXx2051-40 to 125CompensatedAnalogAxial PortGauge0 to 105071 to 1610
MPXx2053-40 to 125CompensatedAnalogSide Port, Dual Side Ports, UnportedGauge, Differential0 to 505071 to 1610
MPXx2100-40 to 125CompensatedAnalogAxial Port, Unported, Dual Side PortsAbsolute, Differential0 to 10010014.51 to 1610
MPXx2102-40 to 125CompensatedAnalogDual Side Ports, Axial Port, Unported, Side PortDifferential, Absolute, Gauge0 to 10010014.51 to 1610
MPXx50502.5, 5-40 to 125IntegratedAnalogUnported, Axial Port, Dual Side Ports, Side PortDifferential, Vacuum, Gauge, Absolute0 to 50507.25, 7.54.75 to 5.25, 2.7 to 3.33, 5
MPXx53-40 to 125UncompensatedAnalogUnported, Side Port, Dual Side PortsDifferential, Gauge0 to 505071 to 63