| 型号 | Series Name | Number of Channels | Configuration [Device] | Automotive | VCES (V) | IC (A) @25 °C | IC (A) @100 °C | VCE(sat) (V) | tf (μs) typ. | tsc (μs) | FRD Vf (V) | FRD trr (ns) | Pch (W) | Application | Mounting Type | Package Type | Production Status | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RJH1CV5DPK | RJH1CVx Series | Single | Built-In FRD | - | 1200 | 50 | 25 | 1.8 | 0.165 | 5 | 1.8 | 170 | 245 | Inverter | Through Hole | TO-3P | Mass Production | |||||||||
| RJH1CV6DPK | RJH1CVx Series | Single | Built-In FRD | - | 1200 | 60 | 30 | 1.8 | 0.12 | 5 | 2 | 180 | 290 | Inverter | Through Hole | TO-3P | Mass Production | |||||||||
| RJH1CV7DPK | RJH1CVx Series | Single | Built-In FRD | - | 1200 | 70 | 35 | 1.8 | 0.28 | 5 | 2.1 | 200 | 320 | Inverter | Through Hole | TO-3P | Mass Production | |||||||||
| RJH60V1BDPE | RJH60Vx Series | Single | Built-In FRD | - | 600 | 16 | 8 | 1.6 | 0.11 | 3 | 2.5 | 25 | 52 | Inverter | Surface Mount | LDPAK(S)-(1) | Mass Production | |||||||||
| RJH60V1BDPP-M0 | RJH60Vx Series | Single | Built-In FRD | - | 600 | 16 | 8 | 1.6 | 0.11 | 3 | 2.5 | 25 | 30 | Inverter | Through Hole | TO-220FL | Mass Production | |||||||||
| RJH60V2BDPE | RJH60Vx Series | Single | Built-In FRD | - | 600 | 25 | 12 | 1.6 | 0.075 | 3 | 2.5 | 25 | 63 | Inverter | Surface Mount | LDPAK(S)-(1) | Mass Production | |||||||||
| RJH60V2BDPP-M0 | RJH60Vx Series | Single | Built-In FRD | - | 600 | 25 | 12 | 1.6 | 0.075 | 3 | 2.5 | 25 | 34 | Inverter | Through Hole | TO-220FL | Mass Production | |||||||||
| RJH60V3BDPE | RJH60Vx Series | Single | Built-In FRD | - | 600 | 35 | 17 | 1.6 | 0.075 | 3 | 2.8 | 25 | 113 | Inverter | Surface Mount | LDPAK(S)-(1) | Mass Production | |||||||||
| RJH60V3BDPP-M0 | RJH60Vx Series | Single | Built-In FRD | - | 600 | 35 | 17 | 1.6 | 0.075 | 3 | 2.8 | 25 | 40 | Inverter | Through Hole | TO-220FL | Mass Production | |||||||||
| RJP60F5DPK | - | Single | - | - | 600 | 80 | 40 | 1.37 | 0.085 | - | - | - | 260.4 | IH Cooker/PFC | Through Hole | TO-3P | Mass Production | |||||||||
| RJH60A83RDPE | RJH60 A8x Series | Single | Built-In FRD | - | 600 | 20 | 10 | 2.1 | 0.045 | 3 | 2.3 | 130 | 52 | Small Motor Controll | Surface Mount | LDPAK(S) | Mass Production | |||||||||
| RJH60A83RDPN-E0 | - | Single | Built-In FRD | - | 600 | 20 | 10 | 2.1 | 0.045 | 3 | 2.3 | 130 | 52 | Small Motor Controll | - | TO-220AB | Mass Production | |||||||||
| RJP60D0DPE | - | Single | - | - | 600 | 45 | 22 | 1.6 | 0.07 | 3 | - | - | 122 | Inverter | Through Hole | LDPAK(S) | Mass Production | |||||||||
| RJH60D5DPM | RJH60Dx Series | Single | Built-In FRD | - | 600 | 75 | 37 | 1.6 | 0.04 | 3 | 1.4 | 100 | 45 | Inverter | Through Hole | TO-3PFM | Mass Production | |||||||||
| RJH60D6DPM | RJH60Dx Series | Single | Built-In FRD | - | 600 | 80 | 40 | 1.6 | 0.05 | 3 | 1.4 | 100 | 50 | Inverter | Through Hole | TO-3PFM | Mass Production | |||||||||
| RJH60D7DPM | RJH60Dx Series | Single | Built-In FRD | - | 600 | 90 | 50 | 1.6 | 0.05 | 3 | 1.4 | 100 | 55 | Inverter | Through Hole | TO-3PFM | Mass Production | |||||||||
| RJP60D0DPP-M0 | - | Single | - | - | 600 | 45 | 22 | 1.6 | 0.07 | 3 | - | - | 35 | Inverter | Through Hole | TO-220FL | Mass Production | |||||||||
| RJH60D0DPM | RJH60Dx Series | Single | Built-In FRD | - | 600 | 45 | 22 | 1.6 | 0.07 | 3 | 1.4 | 100 | 40 | Inverter | Through Hole | TO-3PFM | Mass Production | |||||||||
| RJH60F3DPK | RJH60Fx Series | Single | Built-In FRD | - | 600 | 40 | 20 | 1.4 | 0.092 | - | 1.6 | 140 | 178.5 | IH Cooker/PFC | Through Hole | TO-3P | Mass Production | |||||||||
| RJP6065DPM | - | Single | - | - | 630 | 40 | - | 1.8 | 0.45 | - | - | - | 50 | - | Through Hole | TO-3PFM | Mass Production | |||||||||
| RJH60F0DPQ-A0 | RJH60Fx Series | Single | Built-In FRD | - | 600 | 50 | 25 | 1.4 | 0.09 | - | 1.2 | 90 | 201.6 | IH Cooker/PFC | Through Hole | TO-247A | Mass Production | |||||||||
| RJH60F4DPQ-A0 | RJH60Fx Series | Single | Built-In FRD | - | 600 | 60 | 30 | 1.4 | 0.08 | - | 1.2 | 90 | 235.8 | IH Cooker/PFC | Through Hole | TO-247A | Mass Production | |||||||||
| RJH60F5DPQ-A0 | RJH60Fx Series | Single | Built-In FRD | - | 600 | 80 | 40 | 1.37 | 0.085 | - | 1.2 | 90 | 260.4 | IH Cooker/PFC | Through Hole | TO-247A | Mass Production | |||||||||
| RJH60F6DPQ-A0 | RJH60Fx Series | Single | Built-In FRD | - | 600 | 85 | 45 | 1.35 | 0.074 | - | 1.2 | 90 | 297.6 | IH Cooker/PFC | Through Hole | TO-247A | Mass Production | |||||||||
| RJH60F7DPQ-A0 | RJH60Fx Series | Single | Built-In FRD | - | 600 | 90 | 50 | 1.35 | 0.074 | - | 1.2 | 90 | 328.9 | IH Cooker/PFC | Through Hole | TO-247A | Mass Production | |||||||||
| RJH6087BDPK | RJH608x Series | Single | Built-In FRD | - | 600 | 50 | - | 2.65 | 0.055 | - | 1.4 | 100 | 223.2 | PFC | Through Hole | TO-3P | Mass Production | |||||||||
| RJH6088BDPK | RJH608x Series | Single | Built-In FRD | - | 600 | 60 | - | 2.65 | 0.06 | - | 1.4 | 100 | 268.8 | PFC | Through Hole | TO-3P | Mass Production | |||||||||
| RJH60F3DPQ-A0 | RJH60Fx Series | Single | Built-In FRD | - | 600 | 40 | 20 | 1.4 | 0.092 | - | 1.2 | 90 | 178.5 | IH Cooker/PFC | Through Hole | TO-247A | Mass Production | |||||||||
| RJH1BF6RDPQ-80 | - | Single | Built-In FRD | - | 1100 | 55 | 30 | 1.7 | 0.247 | - | 3 | - | 227.2 | IH Cooker/Inverter | Through Hole | TO-247 | Mass Production | |||||||||
| RJH1BF7RDPQ-80 | - | Single | Built-In FRD | - | 1100 | 60 | 35 | 1.6 | 0.208 | - | 3 | - | 250 | IH Cooker/Inverter | Through Hole | TO-247 | Mass Production | |||||||||
| RJH1CF4RDPQ-80 | - | Single | Built-In FRD | - | 1200 | 40 | 20 | 2 | 0.3 | - | 4.2 | - | 156.2 | IH Cooker/Inverter | Through Hole | TO-247 | Mass Production | |||||||||
| RJH1CF5RDPQ-80 | - | Single | Built-In FRD | - | 1200 | 50 | 25 | 1.95 | 0.272 | - | 4.2 | - | 192.3 | IH Cooker/Inverter | Through Hole | TO-247 | Mass Production | |||||||||
| RJH1CF6RDPQ-80 | - | Single | Built-In FRD | - | 1200 | 55 | 30 | 1.8 | 0.275 | - | 3 | - | 227.2 | IH Cooker/Inverter | Through Hole | TO-247 | Mass Production | |||||||||
| RJH1CF7RDPQ-80 | - | Single | Built-In FRD | - | 1200 | 60 | 35 | 1.85 | 0.25 | - | 3 | - | 250 | IH Cooker/Inverter | Through Hole | TO-247 | Mass Production | |||||||||
| RJH1DF7RDPQ-80 | - | Single | Built-In FRD | - | 1350 | 60 | 35 | 1.95 | 0.208 | - | 3.4 | - | 250 | IH Cooker/Inverter | Through Hole | TO-247 | Mass Production | |||||||||
| RJH60T4DPQ-A0 | - | Single | Built-In FRD | - | 600 | 60 | 30 | 1.7 | 0.072 | - | 1.2 | 100 | 235.8 | IH Cooker | Through Hole | TO-247A | Mass Production | |||||||||
| RJH1CV6DPQ-E0 | RJH1CVx Series | Single | Built-In FRD | - | 1200 | 60 | 30 | 1.8 | 0.12 | 5 | 2 | 180 | 290 | Inverter | Through Hole | TO-247 | Mass Production | |||||||||
| RJH1CV7DPQ-E0 | RJH1CVx Series | Single | Built-In FRD | - | 1200 | 70 | 35 | 1.8 | 0.28 | 5 | 2.1 | 200 | 320 | Inverter | Through Hole | TO-247 | Mass Production | |||||||||
| RJH1CM7DPQ-E0 | RJH1CMx Series | Single | Built-In FRD | - | 1200 | 50 | 25 | 2.1 | 0.105 | 10 | 1.8 | 170 | 328.9 | Inverter | Through Hole | TO-247 | Mass Production | |||||||||
| RJH1CM6DPQ-E0 | RJH1CMx Series | Single | Built-In FRD | - | 1200 | 40 | 20 | 2.1 | 0.12 | 10 | 1.7 | 180 | 290 | Inverter | Through Hole | TO-247 | Mass Production | |||||||||
| RJH1CM5DPQ-E0 | RJH1CMx Series | Single | Built-In FRD | - | 1200 | 30 | 15 | 2.1 | 0.125 | 10 | 1.6 | 200 | 245 | Inverter | Through Hole | TO-247 | Mass Production | |||||||||
| RJH1CV5DPQ-E0 | RJH1CVx Series | Single | Built-In FRD | - | 1200 | 50 | 25 | 1.8 | 0.165 | 5 | 1.8 | 170 | 245 | Inverter | Through Hole | TO-247 | Mass Production | |||||||||
| RJH60M1DPP-M0 | RJH60Mx Series | Single | Built-In FRD | - | 600 | 16 | 8 | 1.9 | 0.07 | 6 | 1.4 | 75 | 30 | Inverter | Through Hole | TO-220FL | Mass Production | |||||||||
| RJH60M1DPE | RJH60Mx Series | Single | Built-In FRD | - | 600 | 16 | 8 | 1.9 | 0.07 | 6 | 1.1 | 100 | 52 | Inverter | Through Hole | LDPAK(S) | Mass Production | |||||||||
| RJH60M2DPP-M0 | RJH60Mx Series | Single | Built-In FRD | - | 600 | 25 | 12 | 1.9 | 0.045 | 6 | 1.2 | 85 | 33.8 | Inverter | Through Hole | TO-220FL | Mass Production | |||||||||
| RJH60M2DPE | RJH60Mx Series | Single | Built-In FRD | - | 600 | 25 | 12 | 1.9 | 0.045 | 6 | 1.2 | 85 | 63 | Inverter | Through Hole | LDPAK(S) | Mass Production | |||||||||
| RJH60M3DPP-M0 | RJH60Mx Series | Single | Built-In FRD | - | 600 | 35 | 17 | 1.8 | 0.07 | 6 | 1.3 | 90 | 39.7 | Inverter | Through Hole | TO-220FL | Mass Production | |||||||||
| RJH60M3DPE | RJH60Mx Series | Single | Built-In FRD | - | 600 | 35 | 17 | 1.8 | 0.07 | 6 | 1.3 | 90 | 113 | Inverter | Surface Mount | LDPAK(S) | Mass Production | |||||||||
| RJP60F0DPE | - | Single | - | - | 600 | 50 | 25 | 1.4 | 0.09 | - | - | - | 122 | IH Cooker/PFC | Surface Mount | LDPAK(S)-(1) | Mass Production | |||||||||
| RJH60D7ADPK | RJH60Dx Series | Single | Built-In FRD | - | 600 | 90 | 50 | 1.6 | 0.05 | 3 | 1.4 | 100 | 300 | Inverter | Through Hole | TO-3P | Mass Production | |||||||||
| RJH6086BDPK | RJH608x Series | Single | Built-In FRD | - | 600 | 45 | - | 2.65 | 0.036 | - | 1.4 | 100 | 198.4 | PFC | Through Hole | TO-3P | Under Development | |||||||||
| RJP60F0DPM | - | Single | - | - | 600 | 50 | 25 | 1.4 | 0.09 | - | - | - | 40 | IH Cooker/PFC | Through Hole | TO-3PFM | Mass Production | |||||||||
| RJP60F4DPM | - | Single | - | - | 600 | 60 | 30 | 1.4 | 0.08 | - | - | - | 41.2 | IH Cooker/PFC | Through Hole | TO-3PFM | Mass Production | |||||||||
| RJP60F5DPM | - | Single | - | - | 600 | 80 | 40 | 1.37 | 0.085 | - | - | - | 45 | IH Cooker/PFC | Through Hole | TO-3PFM | Mass Production | |||||||||
| RJH60F5BDPQ-A0 | RJH60Fx Series | Single | Built-In FRD | - | 600 | 80 | 40 | 1.37 | 0.068 | - | 2.5 | 25 | 260.4 | IH Cooker/PFC | Through Hole | TO-247A | Mass Production | |||||||||
| RJH60F6BDPQ-A0 | RJH60Fx Series | Single | Built-In FRD | - | 600 | 85 | 45 | 1.35 | 0.074 | - | 2.5 | 25 | 297.6 | IH Cooker/PFC | Through Hole | TO-247A | Mass Production | |||||||||
| RJH60F7BDPQ-A0 | RJH60Fx Series | Single | Built-In FRD | - | 600 | 90 | 50 | 1.35 | 0.074 | - | 2.5 | 25 | 328.9 | IH Cooker/PFC | Through Hole | TO-247A | Mass Production | |||||||||
| RJP60V0DPM | - | Single | - | - | 600 | 45 | 22 | 1.5 | 0.07 | 6 | - | - | 40 | Inverter | Through Hole | TO-3PFM | Mass Production | |||||||||
| RJH60D7DPQ-E0 | RJH60Dx Series | Single | Built-In FRD | - | 600 | 90 | 50 | 1.6 | 0.05 | 3 | 1.4 | 100 | 300 | Inverter | Through Hole | TO-247 | Mass Production | |||||||||
| RJH60A83RDPP-M0 | RJH60 A8x Series | Single | Built-In FRD | - | 600 | 20 | 10 | 2.1 | 0.045 | 3 | 2.3 | 130 | 30 | Small Motor Controll | Through Hole | TO-220FL | Mass Production | |||||||||
| RJH60A85RDPE | RJH60 A8x Series | Single | Built-In FRD | - | 600 | 30 | 15 | 1.5 | 0.11 | 3 | 1.7 | 160 | 113 | Small Motor Controll | Surface Mount | LDPAK(S) | Mass Production | |||||||||
| RJH60A85RDPP-M0 | RJH60 A8x Series | Single | Built-In FRD | - | 600 | 30 | 15 | 1.5 | 0.11 | 3 | 1.7 | 160 | 39.7 | Small Motor Controll | - | TO-220FL | Mass Production | |||||||||
| RJH60D5BDPQ-E0 | RJH60Dx Series | Single | Built-In FRD | - | 600 | 75 | 37 | 1.6 | 0.05 | 3 | 2.5 | 25 | 200 | Inverter | Through Hole | TO-247 | Mass Production | |||||||||
| RJH60D7BDPQ-E0 | RJH60Dx Series | Single | Built-In FRD | - | 600 | 90 | 50 | 1.6 | 0.05 | 3 | 2.5 | 25 | 300 | Inverter | Through Hole | TO-247 | Mass Production | |||||||||
| RJP65S03DWT | - | Single | - | - | 650 | 60 | 30 | 1.5 | 0.1 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP65S03DWA | - | Single | - | - | 650 | 60 | 30 | 1.5 | 0.1 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP65S04DWT | - | Single | - | - | 650 | 100 | 50 | 1.5 | 0.1 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP65S04DWA | - | Single | - | - | 650 | 100 | 50 | 1.5 | 0.1 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP65S05DWT | - | Single | - | - | 650 | 150 | 75 | 1.5 | 0.075 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP65S05DWA | - | Single | - | - | 650 | 150 | 75 | 1.5 | 0.075 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP65S06DWT | - | Single | - | - | 650 | 200 | 100 | 1.5 | 0.06 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP65S06DWA | - | Single | - | - | 650 | 200 | 100 | 1.5 | 0.06 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP65S07DWT | - | Single | - | - | 650 | 300 | 150 | 1.5 | 0.07 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP65S07DWA | - | Single | - | - | 650 | 300 | 150 | 1.5 | 0.07 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP65S08DWT | - | Single | - | - | 650 | 400 | 200 | 1.5 | 0.08 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP65S08DWA | - | Single | - | - | 650 | 400 | 200 | 1.5 | 0.08 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP1CS03DWT | - | Single | - | - | 1250 | 60 | 30 | 1.8 | 0.16 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP1CS03DWA | - | Single | - | - | 1250 | 60 | 30 | 1.8 | 0.16 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP1CS04DWT | - | Single | - | - | 1250 | 100 | 50 | 1.8 | 0.16 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP1CS04DWA | - | Single | - | - | 1250 | 100 | 50 | 1.8 | 0.16 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP1CS05DWT | - | Single | - | - | 1250 | 150 | 75 | 1.8 | 0.17 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP1CS05DWA | - | Single | - | - | 1250 | 150 | 75 | 1.8 | 0.17 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP1CS06DWT | - | Single | - | - | 1250 | 200 | 100 | 1.8 | 0.16 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP1CS06DWA | - | Single | - | - | 1250 | 200 | 100 | 1.8 | 0.16 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP1CS07DWT | - | Single | - | - | 1250 | 300 | 150 | 1.8 | 0.15 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP1CS07DWA | - | Single | - | - | 1250 | 300 | 150 | 1.8 | 0.15 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP1CS08DWT | - | Single | - | - | 1250 | 400 | 200 | 1.8 | 0.14 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJP1CS08DWA | - | Single | - | - | 1250 | 400 | 200 | 1.8 | 0.14 | 10 | - | - | - | - | - | - | New Products | |||||||||
| RJQ6008DPM | - | Single | Built-In FRD | - | 600 | 20 | 10 | 2.65 | 0.055 | - | 1.4 | 100 | 48 | - | Through Hole | TO-3PFM5 | Mass Production | |||||||||
| RJQ6003DPM | - | Single | Built-In FRD | - | 600 | 40 | 20 | 1.37 | 0.085 | - | 1.4 | 100 | 50 | - | Through Hole | TO-3PFM5 | Under Development | |||||||||
| RJQ6015DPM | - | Dual | Built-In FRD | - | 600 | 37 | 18 | 1.6 | 0.04 | 3 | 1.4 | 100 | 50 | - | Through Hole | TO-3PFM5 | Under Development | |||||||||
| RJH65S04DPQ-A0 | IGBTs for General use | Single | Built-In FRD | - | 650 | 100 | 50 | 1.6 | 0.08 | - | 1.7 | 180 | 378 | Inverter | Through Hole | TO-247A | New Products | |||||||||
| RJH60D1DPP-E0 | RJH60Dx Series | Single | Built-In FRD | 0 | 600 | 20 | 10 | 1.9 | 0.075 | 3 | 1.4 | 70 | 30 | Inverter | Through Hole | TO-220FP | Mass Production | |||||||||
| RJH60D2DPP-E0 | RJH60Dx Series | Single | Built-In FRD | 0 | 600 | 25 | 12 | 1.7 | 0.08 | 3 | 1.2 | 100 | 34 | Inverter | Through Hole | TO-220FP | Mass Production | |||||||||
| RJP6016JPE | - | Single | - | - | 600 | 40 | - | 1.7 | 0.09 | - | - | - | 112 | Power Switching | Surface Mount | LDPAK(S)-(1) | Mass Production | |||||||||
| RJP1CM7DWT | - | Single | - | - | 1200 | 50 | 25 | 1.9 | 0.15 | 10 | - | - | - | - | - | - | Under Development | |||||||||
| RJP65T43DPM | - | Single | - | - | 650 | 40 | 20 | 1.8 | 0.045 | - | - | - | 68.8 | PFC | Through Hole | TO-3PFM | Mass Production | |||||||||
| RJH60T04DPQ-A1 | - | Single | Built-In FRD | - | 600 | 60 | 30 | 1.5 | 0.045 | - | 1.2 | 100 | 208.3 | IH Cooker | Through Hole | TO-247A | Mass Production | |||||||||
| RJH1BG6RDPK | - | Single | Built-In FRD | - | 1100 | 55 | 30 | 1.7 | 0.247 | - | 3 | - | 227.2 | IH Cooker/Inverter | Through Hole | TO-3P | Mass Production | |||||||||
| RJH1BG7RDPK | - | Single | Built-In FRD | - | 1100 | 60 | 35 | 1.6 | 0.2 | - | 2.7 | - | 300 | IH Cooker/Inverter | Through Hole | TO-3P | Mass Production | |||||||||
| RJP6085DPN-00 | - | Single | - | - | 600 | 40 | - | 2.65 | 0.04 | - | - | - | 178.5 | - | - | TO-220AB | Mass Production | |||||||||
| RJP6085DPK | - | Single | - | - | 600 | 40 | - | 2.65 | 0.04 | - | - | - | 178.5 | - | Through Hole | TO-3P | Mass Production | |||||||||
| RJH60F0DPK | RJH60Fx Series | Single | Built-In FRD | - | 600 | 50 | 25 | 1.4 | 0.09 | - | 1.6 | 140 | 201.6 | IH Cooker/PFC | Through Hole | TO-3P | Mass Production | |||||||||
| RJH60F4DPK | RJH60Fx Series | Single | Built-In FRD | - | 600 | 60 | 30 | 1.4 | 0.08 | - | 1.6 | 140 | 235.8 | IH Cooker/PFC | Through Hole | TO-3P | Mass Production | |||||||||
| RJH60F6DPK | RJH60Fx Series | Single | Built-In FRD | - | 600 | 85 | 45 | 1.35 | 0.074 | - | 1.6 | 140 | 297.6 | IH Cooker/PFC | Through Hole | TO-3P | Mass Production | |||||||||
| RJH60F7ADPK | RJH60Fx Series | Single | Built-In FRD | - | 600 | 90 | 50 | 1.35 | 0.074 | - | 1.6 | 140 | 328.9 | IH Cooker/PFC | Through Hole | TO-3P | Mass Production | |||||||||
| RJH60F5DPK | RJH60Fx Series | Single | Built-In FRD | - | 600 | 80 | 40 | 1.37 | 0.085 | - | 1.6 | 140 | 260.4 | IH Cooker/PFC | Through Hole | TO-3P | Mass Production | |||||||||
| RJH60D1DPP-M0 | RJH60Dx Series | Single | Built-In FRD | - | 600 | 20 | 10 | 1.9 | 0.075 | 3 | 1.4 | 70 | 30 | Inverter | Through Hole | TO-220FL | Mass Production | |||||||||
| RJH60D1DPE | RJH60Dx Series | Single | Built-In FRD | - | 600 | 20 | 10 | 1.9 | 0.075 | 3 | 1.2 | 100 | 52 | Inverter | Surface Mount | LDPAK(S) | Mass Production | |||||||||
| RJH60D2DPP-M0 | RJH60Dx Series | Single | Built-In FRD | - | 600 | 25 | 12 | 1.7 | 0.08 | 3 | 1.2 | 100 | 34 | Inverter | Through Hole | TO-220FL | Mass Production | |||||||||
| RJH60D2DPE | RJH60Dx Series | Single | Built-In FRD | - | 600 | 25 | 12 | 1.7 | 0.08 | 3 | 1.2 | 100 | 63 | Inverter | Surface Mount | LDPAK(S) | Mass Production | |||||||||
| RJH60D3DPP-M0 | - | Single | B-in FRD | - | 600 | 35 | 17 | 1.6 | 0.07 | 3 | 1.3 | 100 | 40 | Inverter | - | TO-220FL | Mass Production | |||||||||
| RJH60D3DPE | RJH60Dx Series | Single | Built-In FRD | - | 600 | 35 | 17 | 1.6 | 0.07 | 3 | 1.3 | 100 | 113 | Inverter | Surface Mount | LDPAK(S) | Mass Production | |||||||||
| RJP60D0DPK | - | Single | - | - | 600 | 45 | 22 | 1.6 | 0.07 | 3 | - | - | 140 | Inverter | Through Hole | TO-3P | Mass Production | |||||||||
| RJH60D5DPK | RJH60Dx Series | Single | Built-In FRD | - | 600 | 75 | 37 | 1.6 | 0.04 | 3 | 1.4 | 100 | 200 | Inverter | Through Hole | TO-3P | Mass Production | |||||||||
| RJH60D6DPK | RJH60Dx Series | Single | Built-In FRD | - | 600 | 80 | 40 | 1.6 | 0.05 | 3 | 1.4 | 100 | 260 | Inverter | Through Hole | TO-3P | Mass Production | |||||||||
| RJH60D7DPK | RJH60Dx Series | Single | Built-In FRD | - | 600 | 90 | 50 | 1.6 | 0.05 | 3 | 1.4 | 100 | 300 | Inverter | Through Hole | TO-3P | Mass Production | |||||||||
| RJH60D0DPK | RJH60Dx Series | Single | Built-In FRD | - | 600 | 45 | 22 | 1.6 | 0.07 | 3 | 1.4 | 100 | 140 | Inverter | Through Hole | TO-3P | Mass Production | |||||||||
| RJP60D0DPM | - | Single | - | - | 600 | 45 | 22 | 1.6 | 0.07 | 3 | - | - | 40 | Inverter | Through Hole | TO-3PFM | Mass Production | |||||||||
| GN6020V4LS | - | Single | - | - | 600 | 20 | - | 2.1 | 0.1 | - | - | - | - | - | - | - | Mass Production | |||||||||