型号 Function Safety standard Target application Package Type Device type Output Type BV (kVr.m.s) VL (V) IL (mA) TA (℃) min. TA (℃) max. Tst (℃) min. Tst (℃) max. VF (V) max. IR (μA) max. ILoff (μA) max. Cout (pF) typ. Ron (ohm) typ. ton (ms) max. toff (ms) max. Production Status
PS7113-1A Standard "UL, BSI(Insulation supplementary), CSA" "Measuring instrument, Tester, FA, Exchange, Sensor" 6DIP Standard normally open 1a 1.5 100 350 -40 85 -40 100 1.4 5 1 250 0.9 3 0.2 Mass Production
PS7113-2A Standard "UL, BSI(Insulation supplementary), CSA" "Measuring instrument, Tester, FA, Exchange, Sensor" 8DIP Standard normally open 2a 1.5 100 350 -40 85 -40 100 1.4 5 1 250 0.9 3 0.2 Mass Production
PS7113L-1A Standard "UL, BSI(Insulation supplementary), CSA" "Measuring instrument, Tester, FA, Exchange, Sensor" 6DIP Standard normally open 1a 1.5 100 350 -40 85 -40 100 1.4 5 1 250 0.9 3 0.2 Mass Production
PS7113L-2A Standard "UL, BSI(Insulation supplementary), CSA" "Measuring instrument, Tester, FA, Exchange, Sensor" 8DIP Standard normally open 2a 1.5 100 350 -40 85 -40 100 1.4 5 1 250 0.9 3 0.2 Mass Production
PS7141-2A Standard, High Break Down Voltage "UL, BSI(Insulation supplementary), CSA" "MODEM, FAX, PBX, STB, Exchange, Automatic meter device, Sensor" 8DIP Standard normally open 2a 1.5 400 150 -40 85 -40 100 1.4 5 1 65 20 1 0.2 Mass Production
PS7141E-1A Standard, High Break Down Voltage "UL, BSI, SEMKO, NEMKO, FIMKO, DEMKO" "Communication devices, Measuring instrument, FA, OA equipment" 6DIP Standard normally open 1a 1.5 400 120 -40 85 -40 100 1.4 5 1 36 36 1 0.2 Mass Production
PS7141E-2A Standard, High Break Down Voltage "UL, BSI(Insulation supplementary)" "MODEM, FAX, PBX, STB, Exchange, Automatic meter device, Sensor" 8DIP Standard normally open 2a 1.5 400 100 -40 85 -40 100 1.4 5 1 36 36 1 0.2 Mass Production
PS7141EL-1A Standard, High Break Down Voltage "UL, BSI, SEMKO, NEMKO, FIMKO, DEMKO" "Communication devices, Measuring instrument, FA, OA equipment" 6DIP Standard normally open 1a 1.5 400 120 -40 85 -40 100 1.4 5 1 36 36 1 0.2 Mass Production
PS7141EL-2A Standard, High Break Down Voltage "UL, BSI(Insulation supplementary)" "MODEM, FAX, PBX, STB, Exchange, Automatic meter device, Sensor" 8DIP Standard normally open 2a 1.5 400 100 -40 85 -40 100 1.4 5 1 36 36 1 0.2 Mass Production
PS7141L-2A Standard, High Break Down Voltage "UL, BSI(Insulation supplementary), CSA" "MODEM, FAX, PBX, STB, Exchange, Automatic meter device, Sensor" 8DIP Standard normally open 2a 1.5 400 150 -40 85 -40 100 1.4 5 1 65 20 1 0.2 Mass Production
PS7160-1A Standard, High Break Down Voltage "UL, BSI(Insulation supplementary), CSA" "Measuring instrument, FA" 6DIP Standard normally open 1a 1.5 600 90 -40 85 -40 100 1.4 5 1 110 42 1.5 0.2 Mass Production
PS7160-2A Standard, High Break Down Voltage "UL, BSI(Insulation supplementary), CSA" "Measuring instrument, FA" 8DIP Standard normally open 2a 1.5 600 90 -40 85 -40 100 1.4 5 1 110 42 1.5 0.2 Mass Production
PS7160L-1A Standard, High Break Down Voltage "UL, BSI(Insulation supplementary), CSA" "Measuring instrument, FA" 6DIP Standard normally open 1a 1.5 600 90 -40 85 -40 100 1.4 5 1 110 42 1.5 0.2 Mass Production
PS7160L-2A Standard, High Break Down Voltage "UL, BSI(Insulation supplementary), CSA" "Measuring instrument, FA" 8DIP Standard normally open 2a 1.5 600 90 -40 85 -40 100 1.4 5 1 110 42 1.5 0.2 Mass Production
PS7241-2A Standard, High Break Down Voltage "UL, BSI(Insulation supplementary), CSA" "MODEM, FAX, PBX, STB, Exchange, Automatic meter device, Sensor" 8SOP Standard normally open 2a 1.5 400 120 -40 85 -40 100 1.4 5 1 65 21 1 0.2 Mass Production
PS7241E-1A Standard, High Break Down Voltage "UL, BSI" "MODEM, FAX, Measuring instrument" 4SOP Standard normally open 1a 1.5 400 120 -40 85 -40 100 1.4 5 1 50 22 1 0.2 Mass Production