The XTR116EVM is intended to provide basic evaluation of XTR116 functionality. The external MOSFET mounted to the EVM is selected randomly from the available sources. The XTR116EVM is initially configured to a basic setup for 0mA to 20 mA with 0 V to 4 V input. Note that the accuracy of R5 (RSET ) used in the EVM is only 0.1%, whereas the XTR116 has greater accuracy. The other resistors are standard 1%. The voltage regulator is set to 5 V.
器件型号 | 名称 | 产品系列 |
XTR116 | 4-20mA 电流环路发送器 | 传感器、传感器调节、4-20mA 发送器 |