PS11011 FLAT-BASE TYPE INSULATED TYPE

技术特性 Features
  • Converter bridge for 3 phase AC-to-DC power conversion.
  • Circuit for dynamic braking of motor regenerative energy.
  • 3-phase IGBT inverter bridge configured by the latest 3rd.generation IGBT and diode technology.
  • Inverter output current capability IO (Note 1):
Type Name
100% load
150% over load
PS11011
0.8A (rms)
1.2A (rms), 1min

(Note 1) : The inverter output current is assumed to be sinusoidal and the peak current value of each of the above loading cases is defined as : IOP = IO ´ Ö`2

综合功能 INTEGRATED FUNCTIONS
  • For inverter side upper-leg IGBTs : Drive circuit, High voltage isolated high-speed level shifting, Short circuit protection (SC).
    Bootstrap circuit supply scheme (single drive power supply) and Under voltage protection (UV).
  • For inverter side lower-leg IGBTs : Drive circuit, Short circuit protection (SC).
    Control supply circuit under- & over- voltage protection (OV/UV).
    System over temperature protection (OT). Fault output signaling circuit (FO) and Current limit warning
    signal output (CL).
  • For Brake circuit IGBT : Drive circuit
  • Warning and Fault signaling :
    FO1 : Short circuit protection for lower-leg IGBTs and Input interlocking against spurious arm shoot-through.
    FO2 : N-side control supply abnormality locking (OV/UV).
    FO3 : System over-temperature protection (OT).
    CL : Warning for inverter current overload condition
  • For system feedback control : Analogue signal feedback reproducing actual inverter output phase currents (3f).
  • Input Interface : 5V CMOS/TTL compatible, Schmitt trigger input, and Arm-Shoot-Through interlock protection.
订购信息 Ordering Information
  • PS11011
应用领域 APPLICATION

Acoustic noise-less 0.1kW/AC200V class 3 phase inverter and other motor control applications

功能框图 Functional Block Diagram

PS11011 功能图框

外观尺寸图 Outline Drawing

PS11011 外观尺寸图


应用技术支持与电子电路设计开发资源下载 版本信息 大小
PS11011 数据资料DataSheet下载:PDF Rev.V2 2 页