The MAX1807/MAX1808 monitor up to five supply rails for an overvoltage condition and provide a latched output when any one of the five supplies exceeds the trip thresholds. The latched output drives an external P-channel load switch to remove power when an over-voltage condition is detected. The latch is reset when a logic low is input to ON or the power supply is cycled. The MAX1807 provides a 28V open-drain fault output that can be used to trigger an alert, trip a resetable fuse, or for other purposes. The MAX1808 includes a low-battery comparator with hysteresis to drive the DP output high, turning off the external P-channel switch when the input voltage is too low. The MAX1807/MAX1808 are available in a miniature 10-pin µMAX® package.
title | Download file |
---|---|
MAX1807-MAX1808 Data Sheet | MAX1807-MAX1808.pdf |
Part Number | Channels | VIN (V) | VIN (V) | Over Voltage Trip Level (V) | Under Voltage Lockout (V) | VGATE (V) | Over Volt. Flag | tGATE (On) (ms) | tGATE (Off) (µs) | Oper. Temp. (°C) | Package/Pins |
---|---|---|---|---|---|---|---|---|---|---|---|
min | max | ||||||||||
MAX1807 | 5 | 2 | 28 | Adjustable (1.1V) | 2.7 | 9.5 | Open-Drain | 40 | 11 | -40 to +85 | µMAX/10 |
MAX1808 | - | µMAX/10 | |||||||||
Part Number | Primary Topology | Monitor/Control Features | VIN (V) | VIN (V) | Package/Pins |
---|---|---|---|---|---|
min | max | ||||
MAX1807 | Amplifier/Buffer | Feedback Integrator Output OVP Shutdown | 4.4 | 28 | µMAX/10 |
MAX1808 | Feedback Integrator Low Batt./POK Output Output OVP Shutdown | µMAX/10 | |||
Part Number | Status | Recommended Replacement | Package | Temp | RoHS |
---|---|---|---|---|---|
MAX1807EUB | No Longer Available | µMAX,;10 pin;15.4 mm² | -40°C to +85°C | No | |
MAX1807EUB+ | Active | µMAX,;10 pin;15.4 mm² | -40°C to +85°C | Lead Free | |
MAX1807EUB+T | Active | µMAX,;10 pin;15.4 mm² | -40°C to +85°C | Lead Free | |
MAX1807EUB-T | No Longer Available | MAX1807EUB+T | µMAX,;10 pin;15.4 mm² | -40°C to +85°C | No |