MAX31850:Cold-Junction Compensated, 1-Wire Thermocouple-to-Digital Converters

Accurate 1-Wire Thermocouple-to-Digital Converter ICs Ease Design Effort and Lower System Cost

The MAX31850/MAX31851 cold-junction compensated, 1-Wire® thermocouple-to-digital converters perform cold-junction compensation and digitize the signal from a K-, J-, N-, T-, S-, R-, or E-type thermocouple. The converters resolve temperatures to 0.25°C, allow readings as high as +1768°C and as low as -270°C, and exhibit thermocouple accuracy of 8 LSBs (2°C) for temperatures ranging from -200°C to +700°C. Communication with the master microcontroller is over a 1-Wire bus that by definition requires only one data line (and ground) for communication. Operating power can be obtained directly from the data line (“parasite power”), eliminating the need for an external power supply. Each device has a unique 64-bit serial code, which allows multiple units to function on the same 1-Wire bus. Therefore, it is simple to use one microcontroller (the master device) to monitor temperature from many thermocouples distributed over a large area. Four location address inputs simplify mapping of individual units to specific locations.

Key Features
  • Integration Reduces Design Time and Lowers System Cost
    • 14-Bit, 0.25°C Resolution
    • Integrated Cold-Junction Compensation
    • Available for Multiple Thermocouples Types: Supports K-, J-, N-, T-, and E-Type (MAX31850); S- and R-Type (MAX31851)
    • Detects Thermocouple Shorts to GND or VDD
    • Detects Open Thermocouple
  • 1-Wire Multiddrop Capability Simplifies Multisensor Systems
    • 1-Wire Interface (Read-Only); Power Can Be Obtained from Interface (Parasite-Powered Mode)
MAX31850, MAX31851: Block Diagram
MAX31850, MAX31851: Block Diagram
Applications/Uses
  • Appliances
  • HVAC
  • Industrial
  • Medical
DataSheet
titleDownload file
MAX31850-MAX31851 Data SheetMAX31850-MAX31851.pdf
Parametrics
Part NumberSensor TypeFunctionsInterfaceChannelsAccuracy
(±°C)
Parasite Pwr.Temp. Resolution
(bits)
Oper. Temp.
(°C)
Package/PinsBudgetary
Price
See Notes
MAX31850RemoteThermocouple-to-Digital Converter1-WireOne2Yes14-40 to +125TDFN/10$3.10 @1k
MAX31851TDFN/10
Design kits & evaluation modules
Quality and Environmental Data
Related Products
  • MAX31855:Cold-Junction Compensated Thermocouple-to-Digital Converter
Ordering Information
Part NumberStatusRecommended ReplacementPackageTempRoHS
MAX31850EATB+ActiveTDFN,;10 pin;11.3 mm²-40°C to +125°CLead Free
MAX31850EATB+TActiveTDFN,;10 pin;11.3 mm²-40°C to +125°CLead Free
MAX31850JATB+ActiveTDFN,;10 pin;11.3 mm²-40°C to +125°CLead Free
MAX31850JATB+TActiveTDFN,;10 pin;11.3 mm²-40°C to +125°CLead Free
MAX31850KATB+ActiveTDFN,;10 pin;11.3 mm²-40°C to +125°CLead Free
MAX31850KATB+TActiveTDFN,;10 pin;11.3 mm²-40°C to +125°CLead Free
MAX31850NATB+ActiveTDFN,;10 pin;11.3 mm²-40°C to +125°CLead Free
MAX31850NATB+TActiveTDFN,;10 pin;11.3 mm²-40°C to +125°CLead Free
MAX31850TATB+ActiveTDFN,;10 pin;11.3 mm²-40°C to +125°CLead Free
MAX31850TATB+TActiveTDFN,;10 pin;11.3 mm²-40°C to +125°CLead Free
MAX31850-MAX31851.pdf MAX31851
MAX31850-MAX31851_cn.pdf MAX31851
MAX31850.pdf MAX31850
MAX31850-MAX31851_cn.pdf MAX31851