The MAX4206 logarithmic amplifier computes the log ratio of an input current relative to a reference current (externally or internally generated) and provides a corresponding voltage output with a default 0.25V/decade scale factor. The device operates from a single +2.7V to +11V supply or from dual ±2.7V to ±5.5V supplies and is capable of measuring five decades of input current across a 10nA to 1mA range. The MAX4206's uncommitted op amp can be used for a variety of functions, including filtering noise, adding offset, and adding additional gain. A 0.5V reference is also included to generate an optional precision current reference using an external resistor, which adjusts the log intercept of the MAX4206. The output-offset voltage and the adjustable scale factor are also set using external resistors. The MAX4206 is available in a space-saving 16-pin thin QFN package (4mm x 4mm x 0.8mm), and is specified for operation over the -40°C to +85°C extended temperature range.
title | Download file |
---|---|
MAX4206 Data Sheet | MAX4206.pdf |
Part Number | VSUPPLY (Single) (V) | VSUPPLY (Single) (V) | VSUPPLY (Dual) (±V) | VSUPPLY (Dual) (±V) | ICC (mA) | Log. Slope (mV/ decade) | Dynamic Range (dB) | Package/Pins | Oper. Temp. (°C) | Budgetary Price |
---|---|---|---|---|---|---|---|---|---|---|
min | max | min | max | typ | See Notes | |||||
MAX4206 | 2.7 | 11 | 2.7 | 5.5 | 3.9 | 250 | 100 | TQFN/16 | -40 to +85 | $3.59 @1k |
Part Number | Status | Recommended Replacement | Package | Temp | RoHS |
---|---|---|---|---|---|
MAX4206ETE | No Longer Available | MAX4206ETE+ | TQFN,;16 pin;16.8 mm² | -40°C to +85°C | No |
MAX4206ETE+ | Active | TQFN,;16 pin;16.8 mm² | -40°C to +85°C | Lead Free | |
MAX4206ETE+T | Active | TQFN,;16 pin;16.8 mm² | -40°C to +85°C | Lead Free | |
MAX4206ETE-T | No Longer Available | MAX4206ETE+T | QFN;16 pin | -40°C to +85°C | See data sheet |
MAX4206EVEKIT# | No Longer Available | KIT; | -40°C to +85°C | See data sheet |