MOSFET - Single - P-channel - Drain-to-source voltage 81 and up vishay

SeriesPackageConfigurationChannelVDS (V)VGS (V)rDS(on) @ 10 V (Ohms)rDS(on) @ 7.5 V (Ohms)rDS(on) @ 6 V (Ohms)rDS(on) @ 4.5 V (Ohms)Qg @ 10 V (nC)Qg @ 4.5 V (nC)Qgs (nC)Qgd (nC)ID Max. (A)PD Max. (W)VGS(th) min (V)RgTyp. (Ohms)
IRF9510S, SiHF9510SD2PAK (TO-263)SINGLEP-100201.28.72.24.1-4.043.02.0
IRFR9110, IRFU9110, SiHFR9110, SiHFU9110DPAK (TO-252)SINGLEP-100201.28.72.24.1-3.125.02.0
IRFD9110, SiHFD9110HVMDIPSINGLEP-100201.28.72.24.12.0
IRFR9110, IRFU9110, SiHFR9110, SiHFU9110IPAK (TO-251)SINGLEP-100201.28.72.24.1-3.125.02.0
IRFL9110, SiHFL9110SOT-223SINGLEP-100201.28.72.24.1-1.13.12.0
IRF9510, SiHF9510TO-220ABSINGLEP-100201.28.72.24.1-4.043.02.0
IRF9520S, SiHF9520SD2PAK (TO-263)SINGLEP-100200.618.03.09.0-6.860.02.0
IRFR9120, IRFU9120, SiHFR9120, SiHFU9120DPAK (TO-252)SINGLEP-100200.618.03.09.0-5.642.02.0
IRFD9120, SiHFD9120HVMDIPSINGLEP-100200.618.03.09.02.0
IRFR9120, IRFU9120, SiHFR9120, SiHFU9120IPAK (TO-251)SINGLEP-100200.618.03.09.0-5.642.02.0
IRFI9520G, SiHFI9520GTO-220 FULLPAKSINGLEP-100200.618.03.09.0-5.237.02.0
IRF9520, SiHF9520TO-220ABSINGLEP-100200.618.03.09.0-6.860.02.0
IRF9530S, SiHF9530SD2PAK (TO-263)SINGLEP-100200.338.06.821.0-12.088.02.0
IRFI9530G, SiHFI9530GTO-220 FULLPAKSINGLEP-100200.338.06.821.0-7.742.02.0
IRF9530, SiHF9530TO-220ABSINGLEP-100200.338.06.821.0-12.088.02.0
IRF9540S, SiHF9540SD2PAK (TO-263)SINGLEP-100200.261.014.029.0-19.0150.02.0
IRFI9540G, SiHFI9540GTO-220 FULLPAKSINGLEP-100200.261.014.029.0-11.048.02.0
IRF9540, SiHF9540TO-220ABSINGLEP-100200.261.014.029.0-19.0150.02.0
IRFP9140, SiHFP9140TO-247ACSINGLEP-100200.261.014.029.0-21.0180.02.0
SUD09P10-195DPAK (TO-252)SINGLEP-100200.1950.2123.211.73.54.88.832.11.05.7
Si7113DNPowerPAK 1212-8SINGLEP-100200.1340.14535.016.54.78.013.252.01.05.3
SUD50P10-43L-GE3DPAK (TO-252)SINGLEP-100200.0430.048106.054.014.026.036.4113.61.04.0
Si7489DPPowerPAK SO-8SINGLEP-100200.0410.047106.054.014.026.028.083.01.04.0
SUM90P10-19LD2PAK (TO-263)SINGLEP-100200.0190.021217.097.042.051.090.0375.01.03.5
SiA485DJPowerPAK SC-70SINGLEP-150202.62.74.20.91.31.615.62.510.0
Si1411DHSC70-6SINGLEP-150202.62.74.20.91.30.521.562.58.5
Si7117DNPowerPAK 1212-8SINGLEP-150201.21.37.71.52.52.1712.52.59.0
Si7317DNPowerPAK 1212-8SINGLEP-150301.21.36.51.51.92.819.82.55.5
Si2325DSSOT-23SINGLEP-150201.21.37.71.52.50.691.252.59.0
Si3437DVTSOP-6SINGLEP-150200.750.7912.28.02.13.91.43.22.08.5
Si7315DNPowerPAK 1212-8SINGLEP-150300.3150.3519.54.85.38.952.02.06.1
Si7115DNPowerPAK 1212-8SINGLEP-150200.2950.31527.523.25.48.48.952.02.06.1
Si4455DYSO-8SINGLEP-150200.2950.31527.523.25.48.42.85.92.06.1
Si7439DPPowerPAK SO-8SINGLEP-150200.090.09588.017.526.55.25.42.03.0
IRF9610S, SiHF9610SD2PAK (TO-263)SINGLEP-20020311.07.04.0-1.820.02.0
IRFR9210, IRFU9210, SiHFR9210, SiHFU9210DPAK (TO-252)SINGLEP-2002038.92.13.9-1.925.02.0
IRFD9210, SiHFD9210HVMDIPSINGLEP-2002038.92.13.92.0
IRFR9210, IRFU9210, SiHFR9210, SiHFU9210IPAK (TO-251)SINGLEP-2002038.92.13.9-1.925.02.0
IRF9610, SiHF9610TO-220SINGLEP-20020311.07.04.0-1.820.02.0
IRFI9610G, SiHFI9610GTO-220 FULLPAKSINGLEP-20020313.03.27.3-2.027.02.0
IRF9620S, SiHF9620SD2PAK (TO-263)SINGLEP-200201.522.012.010.0-3.540.02.0
IRFR9220, IRFU9220, SiHFR9220, SiHFU9220DPAK (TO-252)SINGLEP-200201.520.03.311.0-3.642.02.0
IRFD9220, SiHFD9220HVMDIPSINGLEP-200201.515.03.28.42.0
IRFR9220, IRFU9220, SiHFR9220, SiHFU9220IPAK (TO-251)SINGLEP-200201.520.03.311.0-3.642.02.0
IRFI9620G, SiHFI9620GTO-220 FULLPAKSINGLEP-200201.515.03.28.4-3.030.02.0
IRF9620, SiHF9620TO-220ABSINGLEP-200201.522.012.010.0-3.540.02.0
Si7119DNPowerPAK 1212-8SINGLEP-200201.051.116.210.62.54.93.852.02.05.3
IRF9630S, SiHF9630SD2PAK (TO-263)SINGLEP-200200.829.05.415.0-6.574.02.0
IRFI9630G, SiHFI9630GTO-220 FULLPAKSINGLEP-200200.829.05.415.0-4.335.02.0
IRF9630, SiHF9630TO-220ABSINGLEP-200200.829.05.415.0-6.574.02.0
IRF9640S, SiHF9640S, IRF9640L, SiHF9640LD2PAK (TO-263)SINGLEP-200200.544.07.127.0-11.0125.02.0
IRF9640S, SiHF9640S, IRF9640L, SiHF9640LI2PAK (TO-262)SINGLEP-200200.544.07.127.0-11.0125.02.0
IRFI9640G, SiHFI9640GTO-220 FULLPAKSINGLEP-200200.544.07.127.0-6.140.02.0
IRF9640, SiHF9640TO-220ABSINGLEP-200200.544.07.127.0-11.0125.02.0
IRFP9240, SiHFP9240TO-247ACSINGLEP-200200.544.07.127.0-12.0150.02.0
Si7431DPPowerPAK SO-8SINGLEP-200200.1740.1888.016.525.03.85.42.03.0
IRFR9214, IRFU9214, SiHFR9214, SiHFU9214DPAK (TO-252)SINGLEP-25020314.03.16.8-2.750.02.0
IRFR9214, IRFU9214, SiHFR9214, SiHFU9214IPAK (TO-251)SINGLEP-25020314.03.16.8-2.750.02.0
IRFI9634G, SiHFI9634GTO-220 FULLPAKSINGLEP-25020138.08.018.0-4.135.02.0
IRFR9310, IRFU9310, SiHFR9310, SiHFU9310DPAK (TO-252)SINGLEP-40020713.03.25.0-1.850.02.0
IRFR9310, IRFU9310, SiHFR9310, SiHFU9310IPAK (TO-251)SINGLEP-40020713.03.25.0-1.850.02.0